Product Description
These are telescopic, operated by a single screw and have multiple stages automatically locked / unlocked as the mast is extended / retracted.
The advantage of these masts are that they are rugged in spite of being light, self locking at all stages for extended periods, besides being simple to operate and maintain.
These are being used extensively by defence forces and we are supplying our masts with unique stage lock patented design for greater reliability of operations and free from maintenance.
Technical Specification : Electromechanical Mast-15M | ||||
Technical Parameters | Parameter Values | |||
1. TYPE OF MECHANISM | Electro Mechanical (screw type), with manual cranking back-up. | |||
2. APPLICATION | Ground Based, Mobile | |||
3. POWER SUPPLY | 440V±8% AC, 3 phase, 50Hz | |||
4. ELECTRIC MOTOR | 2HP, 440 V±8 %, 3Phase, vertical mounted, S1 duty, IP 65 protection. | |||
5. MAST HEIGHT FROM THE BASE | Extracted 15000±75 mm | Retracted 2100±25 mm | ||
6. PAY LOAD | 100 Kgs | |||
7. SAIL (WINDAGE) AREA | 2.918 m2 | |||
8. WIND SPEED (KMPH) | Operational : 90 | Survival : 140 | ||
9. DEFLECTION OF THE MAST PERMISSIBLE (IN DEGREES) | ≤1 º at 90 Km/ph (operational wind velocity) with Guy Ropes | |||
10. SPACE REQUIREMENT FOR MOUNTING (mm) | 700 x 400 | |||
11. TIME REQUIRED FOR OPERATION AFTER FITMENT OF ANTENNA | EXTRACTION TIME < 8 min | RETRACTION TIME < 8 min | ||
12. MAST SUPPORT | Mounted at base on platform through L-Frame, supported with Hang on frame, which in turn fastened with ISO corners of shelter. | |||
13. APPLICATION | Mobile | |||
14. ENVIRONMENTAL CONDITIONS | Max Temp Min Temp Humidity | Operational + 55 ºC -20 ºC RH98% at 40 ºC | Storage +70 ºC -30 ºC | |
15. WEIGHT OF MAST (with L frame) | 715 Kgs. max. (Hang on frame excluded) | |||
16. SPECIFICATION OF TELESCOPIC TUBES | Steel Alloy Tubes as per ST52/ IS2062 Specification. | |||
17. HAND STEERING FOR EXTRACTION RETRACTION | Manual cranking standby arrangement provided. | |||
18. SAFETY ARRANGEMENT | IP67 Protection provided on Limit switches at fully extracted and retracted condition. |